Configuration and Diagnostics
6874_en_09 PHOENIX CONTACT 4-95
flWorkFWCtrlRunningUpdate
flWorkFWCtrlAutoUpdate
flWorkFWCtrlConf
OID 1.3.6.1.4.1.4346.11.11.11.2.5
flWorkFWCtrlConfStatus
flWorkFWCtrlConfSave
OID 1.3.6.1.4.1.4346.11.11.11.2.4.6
Syntax Integer
Access Read
Description This object can be used to request the status of the firmware update:
Firmware update not started 1
Executing firmware update 2
Firmware update successful 3
Connection error 4
Incorrect file name 5
Error 6
OID 1.3.6.1.4.1.4346.11.11.11.2.4.7
Syntax Integer
Access Read and write
Description This object can be used to trigger the firmware update with subsequent restart:
No firmware update 1
Execute firmware update 2
OID 1.3.6.1.4.1.4346.11.11.11.2.5.1
Syntax Integer
Access Read
Description This object can be used to request the status of the active device configuration:
Configuration OK - configuration corresponds to the saved configuration 1
Configuration faulty - configuration does not correspond to the
saved configuration, i.e., after a restart the switch could
start with another configuration 2
Configuration saved 3
Saving configuration 4
OID 1.3.6.1.4.1.4346.11.11.11.2.5.2
Syntax Integer
Access Read and write
Description This object can be used to save the device configuration:
Do not save configuration 1